FAULTS AND REMEDIES
SPECIFICATIONS
DIVE UNIT
Motor: 24 volts DC
Speed: Drive arm/motor speed is adjustable in the control box
Size: 135mm wide, 290mm high and 230mm deep
Weight: 13kgs including arms
ELECTRONIC CONTROL BOX
Input Voltage: 240 volts/50Hz AC
Output Voltage: 24 volts DC from control board
Transformer Rating 24 volts AC, 100VA
Control System Microprocessor control unit
Surface mount technology circuit board
Wiring System Via on board terminal blocks
External Box Weatherproof box when used with mounting kit and cable gland, IP56 rated
Transmitter/Receiver ATA model hand held transmitter 4 buttons, code hopping type, 9 VDC batteries included
ATA model receiver two channel code hopping type with over 4.29 billion codes
and 27 transmitter code store capacity. The transmitter frequency is 433.92 MHz.
Size 190mm wide, 240mm high and 100mm deep
Weight 4Kgs
The specifications above are approximate only.
ATA reserve the right to alter specifications at any time without notice in accordance with the Company’s policy of continuous product development.
Page 18
Remote transmitter not functioning New transmitters must be coded to the receiver (refer to page 16).
Check/change the battery in the transmitter.
Having the antenna behind a structure (gate or fence) or out of sight may
reduce optimal range/reception.
Interference from external/outside sources such as baby monitors, or radio
transmitter etc. The best solution is to remove the source causing the in-
terference.
Gate re-opens when closing or stops when opening Check obstruction overload sensitivity adjustment (See Page 12, step 7)
Check for obstructions.
Disengage the drive unit to manual (see page 7) and check the gate is in
good working order (see page 6 step 1.1 & 1.2).
If a P.E. beam is fitted ensure it is clear of obstructions or dirt on the lense
Gate does not open and/or close Check that Control Box is plugged into mains power.
Check that motor is engaged for automatic operation.
Check all wiring from motor and microswitches to the control board are
sound.
Gate or opener requires a service Contact the installer of the opener or local ATA distributor for service.
They will be able to inspect, reset, service, adjust or repair the gate and
opener as necessary.